DIN & Backplane Sockets

DIN-standard sockets and press-fit industrial motherboard connectors for rack-mounted industrial control system backplane interconnects.
Applications:Rack-mounted industrial control systems, backplane interconnects
Reference specifications
Published by the original manufacturer and shown here for selection reference. Contact us to confirm the exact specification of the part we supply.
HARTING DIN 41612 power types (5.08 mm pitch)
Source: HARTING · Checked 2026-10-08- Standards
- IEC 60603-2
- Pitch
- 5.08 mm
- Rated current
- 6 A to 15 A depending on type
- Type D
- Up to 32 contacts, 2 rows, 6 A per contact
- Type E
- Up to 48 contacts, 3 rows, 6 A per contact
- Type F
- Up to 48 contacts, 3 rows, 6 A per contact · supplement types FM (9), F9 (9), 2F (24 contacts)
- Type G
- Up to 64 contacts, 3 rows, 6 A per contact
- Type H / MH
- H16 (16 contacts), H15 (15 contacts), H3 (3 contacts), 3 rows, 15 A per contact · MH supplement 6 A
HARTING DIN 41612 signal types (2.54 mm pitch)
Source: HARTING · Checked 2026-10-08- Standards
- DIN IEC 60603-2
- Pitch
- 2.54 mm
- Contact counts
- Up to 96 contacts per connector, up to 2 A per contact (standard rating)
- Type B
- Up to 64 contacts, 2 rows, 2 A per contact · supplements 2B (32 contacts), 3B (20 contacts)
- Type C
- Up to 96 contacts (extendable to 160), 3 rows (extendable to 5) · supplements 2C (32), 3C (20 contacts)
- Type Q
- Up to 64 contacts, 2 rows, 2 A per contact · supplements 2Q (32), 3Q (20 contacts)
- Type R
- Up to 96 contacts (extendable to 160), 3 rows (extendable to 5) · supplements R (HE11), 2R (48), 3R (30 contacts)
- Type M
- Up to 78 contacts plus 8 special contacts (10 for M inverse) · combines signal, coaxial, high-current, fibre-optic and high-voltage contacts
- Termination
- Wave soldering, press-in, crimp, wrap, reflow soldering THR, solder, solder lug, Faston, IDC, cage-clamp, screw (as listed on the HARTING page)
- Housing material
- Glass-fibre-filled thermoplastic resin, RAL 7032
Original part numbers — HARTING DIN 41612
Source: HARTING · Checked 2026-10-09Original manufacturer part numbers, listed for reference only. These are not LTconnector part numbers; ask us whether we can supply a given number.
- 09 03 196 6922
- DIN-Signal C096MS-3,0C1-2: type C male connector, 96 contacts, 2 A, wave soldering, ≥ 400 mating cycles, −55 to +125 ℃, contact resistance ≤ 20 mΩ, performance level 2 (IEC 60603-2)
- 09 06 015 2912
- DIN-Power H15MT-C1-1: type H15, 15 contacts, 15 A, Faston termination, ≥ 500 mating cycles, −55 to +125 ℃, contact resistance ≤ 8 mΩ
- 09 04 032 3213
- DIN-Power D032-FC-B: type D female connector, 32 contacts, crimp termination, −55 to +125 ℃
Original part numbers — HARTING DIN 41612 connectors (product list, first 96)
Source: HARTING · Checked 2026-10-09Original manufacturer part numbers, listed for reference only. These are not LTconnector part numbers; ask us whether we can supply a given number.
- 09 03 164 6921
- DIN-Signal C064MS-3,0C1-2: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 396 6921
- DIN-Signal C096MS-3,0C1-2-clip: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
- 09 06 148 6901
- DIN-Power F048MS-3,0C1-2: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
- 09 03 296 6824
- DIN-Signal C096FS-2,9C1-2: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 264 6824
- DIN-Signal C064FS-2,9C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 248 6834
- DIN-Power Flow048FS-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
- 09 23 248 6824
- DIN-Signal 2C048FS-2,9C1-2: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 248 3201
- DIN-Power F048FC-B: Female connector, 48 contacts, Crimp termination
- 09 23 148 6921
- DIN-Signal 2C048MS-1C1-2: Male connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 296 6825
- DIN-Signal C096FS-4,5C1-2: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 296 6850
- DIN-Signal C096FP-4,5C1-2: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
- 09 04 132 6921
- DIN-Power D032MS-3,0C1-2: Male connector, 32 contacts, 6 A per contact, angled, Wave soldering termination
Show 82 more
- 09 24 220 6824
- DIN-Signal 3B020FS-2,9C1-2: Female connector, 20 contacts, 2 A per contact, straight, Wave soldering termination
- 09 04 232 6831
- DIN-Power D032FS-4,5C1-2: Female connector, 32 contacts, 6 A per contact, straight, Wave soldering termination
- 09 03 264 6825
- DIN-Signal C064FS-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 115 2932
- DIN-Power H015MS-3,2C1-1-V1: Male connector, 15 contacts, 15 A per contact, angled, Wave soldering termination
- 09 23 248 6825
- DIN-Signal 2C048FS-4,5C1-2: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 215 2821
- DIN-Power H015FS4,0C1-1: Female connector, 15 contacts, 15 A per contact, straight, Wave soldering termination
- 09 23 248 6850
- DIN-Signal 2C048FP-4,5C1-2: Female connector, 48 contacts, 2 A per contact, straight, Press-in termination
- 09 06 148 2901
- DIN-Power F048MS-3,0C1-1: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
- 09 03 264 7825
- DIN-Signal C064FS-4,5C1-3: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 05 148 6921
- DIN-Power E048MS-3,0C1-2: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
- 09 06 248 6835
- DIN-Power F048FS-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
- 09 03 696 6921
- DIN-Signal C096MS-3,0C1-2-cod: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 296 6845
- DIN-Signal C096FS-4,5C1-2-kp: Female connector, 96 contacts, 2 A per contact, Wave soldering termination
- 09 06 115 2911
- DIN-Power H015MS-3,2C1-1: Male connector, 15 contacts, 15 A per contact, angled, Wave soldering termination
- 09 03 164 7921
- DIN-Signal C064MS-3,0C1-3: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 196 2921
- DIN-Signal C096MS-3,0C1-1: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 264 6850
- DIN-Signal C064FP-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Press-in termination
- 09 23 248 2824
- DIN-Signal 2C048FS-2,9C1-1: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 348 6901
- DIN-Power F048MS-3,0C1-2-clip: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
- 09 06 109 3401
- DIN-Power F9MC-B1: Male connector, 9 contacts, Crimp termination
- 09 02 164 6921
- DIN-Signal B064MS-3,0C1-2: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
- 09 06 231 6822
- DIN-Power MH24+7FST4,5C1-2: Female connector, 31 contacts, straight, Wave soldering termination
- 09 23 348 6921
- DIN-Signal 2C048MS-3,0C1-2-clip: Male connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
- 09 06 248 6832
- DIN-Power Flow048FP-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Press-in termination
- 09 06 131 6922
- DIN-Power MH24+7MS-1C1-2-V1: Male connector, 31 contacts, angled, Wave soldering termination
- 09 02 264 6825
- DIN-Signal B064FS-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 05 248 6831
- DIN-Power E048FS-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
- 09 03 796 6825
- DIN-Signal C096FS-4,5C1-2-cod: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 248 6823
- DIN-Power F048FL-9,0C1-2: Female connector, 48 contacts, 6 A per contact, straight, Solder termination
- 09 02 264 6824
- DIN-Signal B064FS-2,9C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 196 7921
- DIN-Signal C096MS-3,0C1-3: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
- 09 22 232 6824
- DIN-Signal 2B032FS-2,9C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 396 6919
- DIN-Signal C096MR-3,0C1-2-clip: Male connector, 96 contacts, 2 A per contact, angled, Reflow termination
- 09 73 296 6801
- DIN-Signal R096FS-3,0C1-2: Female connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
- 09 06 148 6921
- DIN-Power F048MS-3,0C1-2-V1: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
- 09 28 248 6801
- DIN-Signal 2R048FS-3,0C1-2: Female connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
- 09 73 196 6903
- DIN-Signal R096MS-4,0C1-2: Male connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 048 2905
- DIN-Power F48MS-3,5C1-1: Male connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
- 09 02 264 6850
- DIN-Signal B064FP-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Press-in termination
- 09 06 248 6833
- DIN-Power Flow048FS-3,7C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
- 09 04 332 6921
- DIN-Power D032MS-3,0C1-2-clip: Male connector, 32 contacts, 6 A per contact, angled, Wave soldering termination
- 09 25 130 6921
- DIN-Signal 3C030MS-3,0C1-2: Male connector, 30 contacts, 2 A per contact, angled, Wave soldering termination
- 09 23 132 6921
- DIN-Signal 2C032MS-3,0C1-2: Male connector, 32 contacts, 2 A per contact, angled, Wave soldering termination
- 09 22 232 6825
- DIN-Signal 2B032FS-4,5C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 296 7825
- DIN-Signal C096FS-4,5C1-3: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 264 6845
- DIN-Signal C064FS-4,5C1-2-kp: Female connector, 64 contacts, 2 A per contact, Wave soldering termination
- 09 05 048 3202
- DIN-Power E048-FC-B: Female connector, 48 contacts, Crimp termination
- 09 02 364 6921
- DIN-Signal B064MS-3,0C1-2-clip: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 464 6825
- DIN-Signal C064FS-4,5C1-2-clip: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 264 6828
- DIN-Signal C064FD-C1-2: Female connector, 64 contacts, 1 A per contact, straight, IDC termination
- 09 04 232 6832
- DIN-Power D032FS-2,9C1-2: Female connector, 32 contacts, 6 A per contact, straight, Wave soldering termination
- 09 03 296 2825
- DIN-Signal C096FS-4,5C1-1: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 215 2871
- DIN-Power H015FTC1-1: Female connector, 15 contacts, 15 A per contact, straight, Faston termination
- 09 06 132 6931
- DIN-Power F032MS-3,0C1-2: Male connector, 32 contacts, 6 A per contact, angled, Wave soldering termination
- 09 03 296 6421
- DIN-Signal C096FS-13,0C1-2: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 248 2832
- DIN-Power Flow048FP-4,5C1-1: Female connector, 48 contacts, 6 A per contact, straight, Press-in termination
- 09 03 296 6861
- DIN-Signal C096FPW-13,2C1-2: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
- 09 03 096 3214
- DIN-Signal C096FC-B: Female connector, 96 contacts, Crimp termination
- 09 03 496 6825
- DIN-Signal C096FS-4,5C1-2-clip: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 132 6921
- DIN-Signal C032MS-3,0C1-2: Male connector, 32 contacts, 2 A per contact, angled, Wave soldering termination
- 09 06 264 3201
- DIN-Power G064FC-B: Female connector, 64 contacts, Crimp termination
- 09 23 348 6919
- DIN-Signal 2C048MR-3,0C1-2-clip: Male connector, 48 contacts, 2 A per contact, angled, Reflow termination
- 09 02 464 6824
- DIN-Signal B064FS-2,9C1-2-clip: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 05 348 6831
- DIN-Power E048FS-4,5C1-2-clip: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
- 09 03 296 2824
- DIN-Signal C096FS-2,9C1-1: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 73 496 6804
- DIN-Signal R096FR-3,0C1-2-clip CTI 400: Female connector, 96 contacts, 2 A per contact, angled, Reflow termination
- 09 73 264 6801
- DIN-Signal R064FS-3,0C1-2: Female connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
- 09 25 230 6824
- DIN-Signal 3C030FS-2,9C1-2: Female connector, 30 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 148 6925
- DIN-Power F048MS-3,0C1-2-V2: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
- 09 23 148 7921
- DIN-Signal 2C048MS-3,0C1-3: Male connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 796 6850
- DIN-Signal C096FP-4,5C1-2-cod: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
- 09 22 332 6921
- DIN-Signal 2B032MS-3,0C1-1-clip: Male connector, 32 contacts, 2 A per contact, angled, Wave soldering termination
- 09 23 232 6824
- DIN-Signal 2C032FS-2,9C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
- 09 03 196 6951
- DIN-Signal C096MS-3,0C1-2-V2: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 296 2850
- DIN-Signal C096FP-4,5C1-1: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
- 09 02 164 7921
- DIN-Signal B064MS-3,0C1-3: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
- 09 03 296 7824
- DIN-Signal C096FS-2,9C1-3: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
- 09 23 448 6824
- DIN-Signal 2C048FS-2,9C1-2-clip: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
- 09 02 164 6922
- DIN-Signal B064MS-3,0C1-2: Male connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
- 09 23 232 6825
- DIN-Signal 2C032FS-4,5C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
- 09 06 215 2811
- DIN-Power H015FT-4,0C1-1: Female connector, 15 contacts, 15 A per contact, straight, Faston termination
- 09 28 148 6903
- DIN-Signal 2R048MS-4,0C1-2: Male connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
FAQ
How do I check if a DIN & Backplane Sockets series matches my current part?
Search by brand or part family using our Cross-Reference Finder, or contact us directly with your current part number -- we'll verify compatibility before recommending a match.
Can DIN & Backplane Sockets be customized to a specific spec I need?
Yes. When no exact match exists in our catalog, our manufacturing partners can custom-build a solution to your exact requirement.
Do you provide samples for DIN & Backplane Sockets before mass production?
Yes -- we provide samples for your validation before moving to mass supply, so you can confirm fit and function first.
For detailed datasheets or cross-reference comparisons for this series, please contact our technical team.
Don’t see the exact spec you need? See custom manufacturing options →
You May Also Need

Military & Aerospace Circular Connectors
Mil-spec compliant circular connectors for aerospace, defense, and other high-reliability, harsh-environment applications.

Push-Pull Self-Locking Circular Connectors
Push-pull self-locking circular connectors enabling fast one-handed mating and de-mating, combining connection reliability with ease of operation.

Industrial Circular Connectors (M8/M12)
Industry-standard M8/M12 circular connectors for industrial automation, used for field-level sensor and actuator connections.