DIN-standard sockets and press-fit industrial motherboard connectors for rack-mounted industrial control system backplane interconnects.

DIN and backplane sockets follow standardized Eurocard-style connector layouts for rack-mounted industrial control systems, letting individual cards be pulled and replaced from the front of a chassis while the backplane wiring stays fixed -- a serviceability pattern common across PLCs and industrial computing racks.

Applications:Rack-mounted industrial control systems, backplane interconnects

DIN socketDIN 41612PC104

Reference specifications

Published by the original manufacturer and shown here for selection reference. Contact us to confirm the exact specification of the part we supply.

HARTING DIN 41612 power types (5.08 mm pitch)

Source: HARTING · Checked 2026-10-08
Standards
IEC 60603-2
Pitch
5.08 mm
Rated current
6 A to 15 A depending on type
Type D
Up to 32 contacts, 2 rows, 6 A per contact
Type E
Up to 48 contacts, 3 rows, 6 A per contact
Type F
Up to 48 contacts, 3 rows, 6 A per contact · supplement types FM (9), F9 (9), 2F (24 contacts)
Type G
Up to 64 contacts, 3 rows, 6 A per contact
Type H / MH
H16 (16 contacts), H15 (15 contacts), H3 (3 contacts), 3 rows, 15 A per contact · MH supplement 6 A

HARTING DIN 41612 signal types (2.54 mm pitch)

Source: HARTING · Checked 2026-10-08
Standards
DIN IEC 60603-2
Pitch
2.54 mm
Contact counts
Up to 96 contacts per connector, up to 2 A per contact (standard rating)
Type B
Up to 64 contacts, 2 rows, 2 A per contact · supplements 2B (32 contacts), 3B (20 contacts)
Type C
Up to 96 contacts (extendable to 160), 3 rows (extendable to 5) · supplements 2C (32), 3C (20 contacts)
Type Q
Up to 64 contacts, 2 rows, 2 A per contact · supplements 2Q (32), 3Q (20 contacts)
Type R
Up to 96 contacts (extendable to 160), 3 rows (extendable to 5) · supplements R (HE11), 2R (48), 3R (30 contacts)
Type M
Up to 78 contacts plus 8 special contacts (10 for M inverse) · combines signal, coaxial, high-current, fibre-optic and high-voltage contacts
Termination
Wave soldering, press-in, crimp, wrap, reflow soldering THR, solder, solder lug, Faston, IDC, cage-clamp, screw (as listed on the HARTING page)
Housing material
Glass-fibre-filled thermoplastic resin, RAL 7032

Original part numbers — HARTING DIN 41612

Source: HARTING · Checked 2026-10-09

Original manufacturer part numbers, listed for reference only. These are not LTconnector part numbers; ask us whether we can supply a given number.

09 03 196 6922
DIN-Signal C096MS-3,0C1-2: type C male connector, 96 contacts, 2 A, wave soldering, ≥ 400 mating cycles, −55 to +125 ℃, contact resistance ≤ 20 mΩ, performance level 2 (IEC 60603-2)
09 06 015 2912
DIN-Power H15MT-C1-1: type H15, 15 contacts, 15 A, Faston termination, ≥ 500 mating cycles, −55 to +125 ℃, contact resistance ≤ 8 mΩ
09 04 032 3213
DIN-Power D032-FC-B: type D female connector, 32 contacts, crimp termination, −55 to +125 ℃

Original part numbers — HARTING DIN 41612 connectors (product list, first 96)

Source: HARTING · Checked 2026-10-09

Original manufacturer part numbers, listed for reference only. These are not LTconnector part numbers; ask us whether we can supply a given number.

09 03 164 6921
DIN-Signal C064MS-3,0C1-2: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
09 03 396 6921
DIN-Signal C096MS-3,0C1-2-clip: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
09 06 148 6901
DIN-Power F048MS-3,0C1-2: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
09 03 296 6824
DIN-Signal C096FS-2,9C1-2: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 03 264 6824
DIN-Signal C064FS-2,9C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 06 248 6834
DIN-Power Flow048FS-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
09 23 248 6824
DIN-Signal 2C048FS-2,9C1-2: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
09 06 248 3201
DIN-Power F048FC-B: Female connector, 48 contacts, Crimp termination
09 23 148 6921
DIN-Signal 2C048MS-1C1-2: Male connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
09 03 296 6825
DIN-Signal C096FS-4,5C1-2: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 03 296 6850
DIN-Signal C096FP-4,5C1-2: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
09 04 132 6921
DIN-Power D032MS-3,0C1-2: Male connector, 32 contacts, 6 A per contact, angled, Wave soldering termination
Show 82 more
09 24 220 6824
DIN-Signal 3B020FS-2,9C1-2: Female connector, 20 contacts, 2 A per contact, straight, Wave soldering termination
09 04 232 6831
DIN-Power D032FS-4,5C1-2: Female connector, 32 contacts, 6 A per contact, straight, Wave soldering termination
09 03 264 6825
DIN-Signal C064FS-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 06 115 2932
DIN-Power H015MS-3,2C1-1-V1: Male connector, 15 contacts, 15 A per contact, angled, Wave soldering termination
09 23 248 6825
DIN-Signal 2C048FS-4,5C1-2: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
09 06 215 2821
DIN-Power H015FS4,0C1-1: Female connector, 15 contacts, 15 A per contact, straight, Wave soldering termination
09 23 248 6850
DIN-Signal 2C048FP-4,5C1-2: Female connector, 48 contacts, 2 A per contact, straight, Press-in termination
09 06 148 2901
DIN-Power F048MS-3,0C1-1: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
09 03 264 7825
DIN-Signal C064FS-4,5C1-3: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 05 148 6921
DIN-Power E048MS-3,0C1-2: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
09 06 248 6835
DIN-Power F048FS-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
09 03 696 6921
DIN-Signal C096MS-3,0C1-2-cod: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
09 03 296 6845
DIN-Signal C096FS-4,5C1-2-kp: Female connector, 96 contacts, 2 A per contact, Wave soldering termination
09 06 115 2911
DIN-Power H015MS-3,2C1-1: Male connector, 15 contacts, 15 A per contact, angled, Wave soldering termination
09 03 164 7921
DIN-Signal C064MS-3,0C1-3: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
09 03 196 2921
DIN-Signal C096MS-3,0C1-1: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
09 03 264 6850
DIN-Signal C064FP-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Press-in termination
09 23 248 2824
DIN-Signal 2C048FS-2,9C1-1: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
09 06 348 6901
DIN-Power F048MS-3,0C1-2-clip: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
09 06 109 3401
DIN-Power F9MC-B1: Male connector, 9 contacts, Crimp termination
09 02 164 6921
DIN-Signal B064MS-3,0C1-2: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
09 06 231 6822
DIN-Power MH24+7FST4,5C1-2: Female connector, 31 contacts, straight, Wave soldering termination
09 23 348 6921
DIN-Signal 2C048MS-3,0C1-2-clip: Male connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
09 06 248 6832
DIN-Power Flow048FP-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Press-in termination
09 06 131 6922
DIN-Power MH24+7MS-1C1-2-V1: Male connector, 31 contacts, angled, Wave soldering termination
09 02 264 6825
DIN-Signal B064FS-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 05 248 6831
DIN-Power E048FS-4,5C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
09 03 796 6825
DIN-Signal C096FS-4,5C1-2-cod: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 06 248 6823
DIN-Power F048FL-9,0C1-2: Female connector, 48 contacts, 6 A per contact, straight, Solder termination
09 02 264 6824
DIN-Signal B064FS-2,9C1-2: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 03 196 7921
DIN-Signal C096MS-3,0C1-3: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
09 22 232 6824
DIN-Signal 2B032FS-2,9C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
09 03 396 6919
DIN-Signal C096MR-3,0C1-2-clip: Male connector, 96 contacts, 2 A per contact, angled, Reflow termination
09 73 296 6801
DIN-Signal R096FS-3,0C1-2: Female connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
09 06 148 6921
DIN-Power F048MS-3,0C1-2-V1: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
09 28 248 6801
DIN-Signal 2R048FS-3,0C1-2: Female connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
09 73 196 6903
DIN-Signal R096MS-4,0C1-2: Male connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 06 048 2905
DIN-Power F48MS-3,5C1-1: Male connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
09 02 264 6850
DIN-Signal B064FP-4,5C1-2: Female connector, 64 contacts, 2 A per contact, straight, Press-in termination
09 06 248 6833
DIN-Power Flow048FS-3,7C1-2: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
09 04 332 6921
DIN-Power D032MS-3,0C1-2-clip: Male connector, 32 contacts, 6 A per contact, angled, Wave soldering termination
09 25 130 6921
DIN-Signal 3C030MS-3,0C1-2: Male connector, 30 contacts, 2 A per contact, angled, Wave soldering termination
09 23 132 6921
DIN-Signal 2C032MS-3,0C1-2: Male connector, 32 contacts, 2 A per contact, angled, Wave soldering termination
09 22 232 6825
DIN-Signal 2B032FS-4,5C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
09 03 296 7825
DIN-Signal C096FS-4,5C1-3: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 03 264 6845
DIN-Signal C064FS-4,5C1-2-kp: Female connector, 64 contacts, 2 A per contact, Wave soldering termination
09 05 048 3202
DIN-Power E048-FC-B: Female connector, 48 contacts, Crimp termination
09 02 364 6921
DIN-Signal B064MS-3,0C1-2-clip: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
09 03 464 6825
DIN-Signal C064FS-4,5C1-2-clip: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 03 264 6828
DIN-Signal C064FD-C1-2: Female connector, 64 contacts, 1 A per contact, straight, IDC termination
09 04 232 6832
DIN-Power D032FS-2,9C1-2: Female connector, 32 contacts, 6 A per contact, straight, Wave soldering termination
09 03 296 2825
DIN-Signal C096FS-4,5C1-1: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 06 215 2871
DIN-Power H015FTC1-1: Female connector, 15 contacts, 15 A per contact, straight, Faston termination
09 06 132 6931
DIN-Power F032MS-3,0C1-2: Male connector, 32 contacts, 6 A per contact, angled, Wave soldering termination
09 03 296 6421
DIN-Signal C096FS-13,0C1-2: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 06 248 2832
DIN-Power Flow048FP-4,5C1-1: Female connector, 48 contacts, 6 A per contact, straight, Press-in termination
09 03 296 6861
DIN-Signal C096FPW-13,2C1-2: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
09 03 096 3214
DIN-Signal C096FC-B: Female connector, 96 contacts, Crimp termination
09 03 496 6825
DIN-Signal C096FS-4,5C1-2-clip: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 03 132 6921
DIN-Signal C032MS-3,0C1-2: Male connector, 32 contacts, 2 A per contact, angled, Wave soldering termination
09 06 264 3201
DIN-Power G064FC-B: Female connector, 64 contacts, Crimp termination
09 23 348 6919
DIN-Signal 2C048MR-3,0C1-2-clip: Male connector, 48 contacts, 2 A per contact, angled, Reflow termination
09 02 464 6824
DIN-Signal B064FS-2,9C1-2-clip: Female connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 05 348 6831
DIN-Power E048FS-4,5C1-2-clip: Female connector, 48 contacts, 6 A per contact, straight, Wave soldering termination
09 03 296 2824
DIN-Signal C096FS-2,9C1-1: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 73 496 6804
DIN-Signal R096FR-3,0C1-2-clip CTI 400: Female connector, 96 contacts, 2 A per contact, angled, Reflow termination
09 73 264 6801
DIN-Signal R064FS-3,0C1-2: Female connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
09 25 230 6824
DIN-Signal 3C030FS-2,9C1-2: Female connector, 30 contacts, 2 A per contact, straight, Wave soldering termination
09 06 148 6925
DIN-Power F048MS-3,0C1-2-V2: Male connector, 48 contacts, 6 A per contact, angled, Wave soldering termination
09 23 148 7921
DIN-Signal 2C048MS-3,0C1-3: Male connector, 48 contacts, 2 A per contact, angled, Wave soldering termination
09 03 796 6850
DIN-Signal C096FP-4,5C1-2-cod: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
09 22 332 6921
DIN-Signal 2B032MS-3,0C1-1-clip: Male connector, 32 contacts, 2 A per contact, angled, Wave soldering termination
09 23 232 6824
DIN-Signal 2C032FS-2,9C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
09 03 196 6951
DIN-Signal C096MS-3,0C1-2-V2: Male connector, 96 contacts, 2 A per contact, angled, Wave soldering termination
09 03 296 2850
DIN-Signal C096FP-4,5C1-1: Female connector, 96 contacts, 2 A per contact, straight, Press-in termination
09 02 164 7921
DIN-Signal B064MS-3,0C1-3: Male connector, 64 contacts, 2 A per contact, angled, Wave soldering termination
09 03 296 7824
DIN-Signal C096FS-2,9C1-3: Female connector, 96 contacts, 2 A per contact, straight, Wave soldering termination
09 23 448 6824
DIN-Signal 2C048FS-2,9C1-2-clip: Female connector, 48 contacts, 2 A per contact, straight, Wave soldering termination
09 02 164 6922
DIN-Signal B064MS-3,0C1-2: Male connector, 64 contacts, 2 A per contact, straight, Wave soldering termination
09 23 232 6825
DIN-Signal 2C032FS-4,5C1-2: Female connector, 32 contacts, 2 A per contact, straight, Wave soldering termination
09 06 215 2811
DIN-Power H015FT-4,0C1-1: Female connector, 15 contacts, 15 A per contact, straight, Faston termination
09 28 148 6903
DIN-Signal 2R048MS-4,0C1-2: Male connector, 48 contacts, 2 A per contact, straight, Wave soldering termination

FAQ

How do I check if a DIN & Backplane Sockets series matches my current part?

Search by brand or part family using our Cross-Reference Finder, or contact us directly with your current part number -- we'll verify compatibility before recommending a match.

Can DIN & Backplane Sockets be customized to a specific spec I need?

Yes. When no exact match exists in our catalog, our manufacturing partners can custom-build a solution to your exact requirement.

Do you provide samples for DIN & Backplane Sockets before mass production?

Yes -- we provide samples for your validation before moving to mass supply, so you can confirm fit and function first.

For detailed datasheets or cross-reference comparisons for this series, please contact our technical team.

Don’t see the exact spec you need? See custom manufacturing options →

You May Also Need

Technical Guides